OPTION 1 - FOUR Wires connection:
- Connect the LI receptacle terminal to the incoming BLACK electrical
supply wire (Ll-hot wire)
- Connect the L2 receptacle terminal to the incoming RED electrical
supply wire (L2-hot wire)
- Connect the NEUTRAL receptacle terminal to the incoming NEUTRAL
(WHITE) electrical supply wire
- Connect the GROUND receptacle terminal to
the incoming GROUND (GREEN) electrical supply wire
OPTION 2 - THREE-Wires connection:
- Connect the LI receptacle terminal to the incoming BLACK electrical
supply wire (Ll-hot wire)
- Connect the L2 receptacle terminal to the incoming RED electrical
supply wire (L2-hot wire)
- Connect the NEUTRAL with the GROUND receptacle terminal to the
incoming NEUTRAL
(WHITE) electrical supply wire
DO NOT USE EXTENSION CORDS WITH THIS APPLIANCE AS IT MAY
RESULT IN FIRE, ELECTRIC SHOCK OR OTHER type of PERSONAL
INJURY.
The appliance is equipped at the factory with an electric supply cord
set 4 wires type with ring terminals (LI, L2, N, Ground) suitable for
range use UL/CSA listed type SRDT/DRT 2x6AWG (LI, L2)+2x8AWG
(N, G) rated 300V, 40 or 50A with fused plug type NEMA 14-50P;
cable length 1,5 m.; in case the supply cord set must be replaced,
it shall be replaced with an identical set having the same technical
specs and following carefully the instructions and diagrams below:
INSTALL GUIDE
Check your local code for which of the options below should be used
in grounding the receptacle power supply connections.