ELECTRICAL
A properly grounded and horizontally-mounted electrical receptacle
Type NEMA 14-50R should be installed no higher than 3" (7.6 cm)
above the floor, no less than 2" (5 cm) and no more than 8" (20,3 cm)
from the left side (facing product); refer to ELECTRICAL CONNECTION
section pag. 13.Check all local code requirements.
GAS
An agency-approved, properly-sized manual shut¬off valve should be
installed no higher than 3" (7.6 cm) above the floor and no less than 2"
(5 cm) and no more than 8" (20.3 cm) from the right side (facing
product).To connect gas between shut-off valve and regulator, use
agency-approved, properly sized flexible or rigid pipe. Check all local
code requirements.
EXHAUST HOOD INSTALLATION
This range will best perform when used with exhaust hoods. These
hoods have been designed to work in conjunction with the range and
have the same finish for a perfect look.For maximum performance, the
height of the bottom of the hood from the worktop should be between
30" (76.2 cm) and 36" (91.4 cm). This would typically result in the
bottom of the hood being 61 1/2" (156.2 cm) to 67 1/2" (171.5 cm)
above the floor. These measurements provide for safe and efficient
operation of the hood.Before installation of the exhaust hood, consult
local or regional building and installation codes for additional specific
clearance requirements.Refer to the range hood installation
instructions provided by the manufacturer for additional information.